岸電箱控制控制變壓器規(guī)格表
型號(hào) | Bmax(mm> | Dmax(mm> | Emax(mm> | 安裝孔距 A(mm> | 安裝孔距 | 安裝孔 | Fmax(mm> |
C(mm> | KxJ(mm> | ||||||
JBK3/JBK5-40, 63 | 78 | 65 | 80 | 56 | 46 | 5x8 | 1 |
JBK3/JBK5-100 | 84 | 84 | 92 | 64 | 64 | 5x9 | 2 |
JBK3/JBK5-160 | 96 | 90 | 100 | 84 | 70 | 6.5x11 | 1.5 |
JBK3/JBK5-250 | 96 | 105 | 100 | 84 | 83 | 6.5x11 | 1.5 |
JBK3/JBK5-500 | 120 | 120 | 125 | 90 | 97 | 7x13 | 1.5 |
JBK3/JBK5-630 | 150 | 130 | 145 | 122 | 100 | 7.5x20 | 2 |
JBK3/JBK5-1000 | 150 | 130 | 145 | 122 | 100 | 7.5x20 | 2 |
JBK3/JBK5-1500 | 168 | 145 | 160 | 130 | 110 | 8x20 | 2 |
JBK3/JBK5-2000 | 168 | 145 | 180 | 130 | 110 | 8x20 | 2 |
JBK3/JBK5-2500 | 250 | 200 | 175 | 200 | 200 | 8x20 | 2 |
JBK3/JBK5-3000 | 250 | 200 | 180 | 200 | 200 | 8x20 | 2 |
JBK3-4000 | 250 | 200 | 185 | 200 | 200 | 7.5x12.5 | 3 |
JBK3-5000 | 250 | 200 | 195 | 200 | 200 | 7.5x12.5 | 3 |
1.常規(guī)額定輸入電壓:440V/380V/220V,特殊輸入電壓要求可根據(jù)用戶需求設(shè)計(jì)生產(chǎn);
2.常規(guī)額定輸出電壓:控制變壓器有110V/127V/220V;照明變壓器有34V/36V;信號(hào)控制變壓器有6V/12V等。
VDE 0550,
JB 5555-2002,
GB 19212.3-2006,
JB/T 8750-1998,
GB 9706.1-2007
岸電箱控制變壓器材質(zhì):
鐵芯材質(zhì)為優(yōu)質(zhì)高矽硅鋼片,導(dǎo)線為耐溫180度耐壓2500V(相對(duì)5000V),有效降低產(chǎn)品運(yùn)行時(shí)損耗,確保產(chǎn)品的穩(wěn)定性。生產(chǎn)中采用真空含浸并使用H級(jí)絕緣材質(zhì),大大降低絕緣耐壓隱患,極大的提高了產(chǎn)品安全性及使用壽命。
名稱 岸電箱控制變壓器 型號(hào) JBK3(63VA-5000VA)
輸入電壓 110V、220V、380V、690V(客戶可以自定電壓)
輸出電壓 6V、6.3V、9V、12V、24V、48V、100V、110V、120V、220V(客戶可以自定電壓)
效率 97%
波形失真 無附加波形失真
保護(hù) 具有過流保護(hù),可連續(xù)無人值守工作
絕緣電阻 ≥150MΩ
電氣強(qiáng)度 工頻正弦電壓2500V歷時(shí)1分鐘無擊穿及閃絡(luò)現(xiàn)象
過載能力 二倍的額定電流,維持1分鐘
環(huán)境溫度 -15-+40(℃)
相對(duì)濕度 <90%
溫升 155攝氏度(含環(huán)境溫度)
耐壓 2500V無擊穿
絕緣等級(jí) H級(jí)
噪音 <45db
注:岸電箱控制變壓器必須為隔離變壓器而不是自耦變壓器,否則不僅不能對(duì)設(shè)備起到保養(yǎng)維護(hù)的效果,更可能對(duì)操作人員造成人身觸電危害!